Gallery: Contributor inviCRO

[X] Close

Welcome to the new SPECT-CT.com

We have migrated the old SPECT-CT.com website to become an iPACS plugin named Image Gallery.

« | < | 1 | > | »
Quintuple Image Co-Registration
Contributor: inviCRO

Tags: Rat , SPECT/CT , Tc-99m , I-123 , Tl-201 , Multi-Isotope , Whole-body , Movie

A quadruple isotope SPECT/CT imaging acquisition was performed on a rat. 450uCi (17MBq) of Tc99m-MDP, 1.4mCi (52MBq) of I123, 600uCi (22MBq) of In111, and 1mCi (37MBq) of Tl201-Chloride were administered to the rat. A 40-minute image acquisition was performed at 3 hours post-injection of the Tc99m/I123 and 1 hour post-injection of the In111/Tl201.

The color bars from left to right are: CT, Tc99m, I123, In111 and Tl201.

Please see [158] for more details.

Data courtesy of the University of New Mexico College of Pharmacy.

Options Details | Download | Contributor
Inflammation imaging in ferrets
Contributor: inviCRO

Tags: SPECT/CT , In-111 , Movie , Ferret

A cohort of ferrets was induced with the flu in an attempt to visualize uptake of radiotracer in the sinuses. In this trial experiment 590uCi of In-111 (green) labeled with an inflammation targeting agent were injected. A fast, 7-minute CT acquisition was acquired over a 230mm scan range followed by a 20-minute SPECT acquisition. In-111 uptake in the trachea, heart, and lymphatic regions is clearly visible. Note also the striations visible in the ferret's trachea.

Images courtesy of the University of New Mexico, College of Pharmacy, and the Lovelace Respiratory Research Institute.

Options Details | Download | Contributor
Demonstration of crosstalk correction between Tc-99m and I-123
Contributor: inviCRO

Tags: Rat , SPECT/CT , Dual-Isotope , Tc-99m , I-123 , Whole-body , Movie

Dual-isotope SPECT/CT imaging was performed on a rat following administration of Tc99m-MDP (450uCi, 17MBq) and I123 (1.4mCi, 52MBq). Image data were acquired for 60 minutes at 60 minutes post-injection. The image displays two reconstructions of the Tc99m SPECT projection data. In the left-hand image, no corrections have been included to account for crosstalk of down-scattered I123 photons into the Tc99m energy window. Therefore, uptake in the thyroid and small intestine is clearly visible. In the right-hand image, a crosstalk correction method has been applied. The evidence of the I123 distribution is eliminated without degradation of the reconstruction of the Tc99m distribution.

Images courtesy of The University of New Mexico, College of Pharmacy.

Options Details | Download | Contributor
inviCRO Onion Model: Respiratory analysis
Contributor: inviCRO

Tags: Rat , SPECT/CT , Tc-99m , Animation , Segmentation , Movie

A three-part animation displaying the results of an automated lung segmentation of a rat using the newly developed inviCRO digital scalpel. The layered model or "onion" model of the lung is then generated via topographical thinning or "peeling" of the segmented lung. Application of this model to the image data allows for automated, quantifiable deposition of the relevant radiopharmaceutical in the lung. The three scenes are comprised of an X-Ray CT/Onion model fusion, SPECT/CT and lastly SPECT/Onion model.

Options Details | Download | Contributor
CT-based brain segmentation in a mouse (slices)
Contributor: inviCRO

Tags: Mouse , CT only , Animation , Segmentation , Brain Study , Movie , Skull

Exemplary segmentation of a mouse brain using the CT component of a NanoSPECT/CT image only. On the left hand side, the original CT slices are shown, while the right images displays a fusion with the four different classifications of this image (background=gray, body=red, bone=white, brain=yellow).

Such classified anatomical data can subsequently be used to isolate organs from other modalities and thus achieve very precise and reliable information on, for instance, uptake.
See [141] for further details.

InviCRO offers tools for automated segmentation for this and many other applications.

Options Details | Download | Contributor
Automatic Tumor segmentation in Mouse (Volume rendering)
Contributor: inviCRO

Tags: Mouse , SPECT/CT , Tc-99m , Segmentation , Movie , Oncology

Example of an automated tumor segmentation in a mouse using Definiens' Developer XD software.
On the left, a volume rendering of the mouse torso (CT in grayscale, SPECT in NIH Fire 2) is shown, while on the right hand side, the tumor was isolated using inviCRO's digital scalpel tool.

The segmentation rule set provided by the Boston-based contract research organization finds the tumor based on its characteristics in the anatomical CT only. This approach not only allows a very precise volume measurement (including necrotic parts of the tumor), but also delivers highly consistent estimates of the tumor uptake from the SPECT image. SPECT and CT images generated on Bioscan's NanoSPECT/CT.

Please note, that different SPECT color scales where used in the left and right movie.

Special thanks to Dr. Hesterman (Bioscan) for his support in data pre-processing and image generation. The mouse image is courtesy of Ben Gershman (Univ. New Mexico).

Options Details | Download | Contributor
Inhalant aerosol imaging in a rat (automatic segmenation of lungs)
Contributor: inviCRO

Tags: Rat , CT only , Segmentation , Movie , Respiratory

To analyze the aerosol images shown in [131] and [133], inviCRO developed a segmentation rule set for Definiens' Developer XD software. This does not only allow for very precise and consistent segmentation of a single image, but can easily be used for batch-processing of an array of images.
The CT-only based segmentation delivers valuable anatomical information to analyze the information gained from the SPECT scans. To isolate the lungs from the rest of the image, inviCRO used their digital scalpel.

Special thanks to Ky Harlin (inviCRO, LLC) for the image processing. For additional details on the mouse data, please see above links.

Options Details | Download | Contributor
Tri-modality rat brain data: Application of CT brain segmentation
Contributor: inviCRO

Tags: Rat , SPECT/CT , MRI , I-125 , Segmentation , Movie

A tri-modality (grayscale MRI, green SPECT, NIH Fire2 CT) MIP of a rat brain acquired by inviCRO at the Center for Translational Neuroimaging in the newly created imaging facility at Northeastern University.

A rule set (written in the Definiens Developer package) was applied to the CT data to automatically segment the brain and bones. The resulting segmentation was used in inviCRO's digital scalpel to isolate brain from the MR and SPECT data with anatomical reference supplied by the bone CT data.

The MRI (100umx100umx500um, 30min acq.) was acquired on a 7T Bruker magnet using a spin-echo sequence (RARE) comprised of 50 slices with 6 averages. The SPECT (600um voxels, 30min acq.) and CT (400um voxels, 4.5min acq.) images were generated on a NanoSPECT/CT. 400 uCi of I125-beta-CIT (a dopamine and serotonin transporter imaging agent) was injected 4.5 hours prior to the SPECT study.

After this process, the image data is now ready for futher analysis, such as estimating uptake in different regions of the brain.

The unsegmented data can be found in [139] and [138].

Special thanks to Dr. Hesterman (Bioscan) for the data processing.

Options Details | Download | Contributor
Tri-modality rat brain data: Transverse slices of brain segmentation
Contributor: inviCRO

Tags: Rat , SPECT/CT , MRI , I-125 , Segmentation , Skull , Slices

The transverse slices of rat brain data with MRI (grayscale), CT (NIH Fire 2), and SPECT (green) acquired by inviCRO at the Center for Translational Neuroimaging in the newly created imaging facility at Northeastern University (using a 7R Bruker magnet and Bioscan's NanoSPECT/CT).

Please see entry [141] for further details.
The unsegmented data can be found in [139] and [138].

Options Details | Download | Contributor
Triple Modality Rat Study (MR, SPECT, CT; slices)
Contributor: inviCRO

Tags: Rat , SPECT/CT , MRI , I-125 , Movie , Skull , Slices

Transverse slices from a tri-modality study (MRI, SPECT, CT) of a rat brain acquired at the Center for Translational Neuroimaging in the newly created imaging facility at Northeastern University. The MRI (grayscale, 100umx100umx500um, 30min acq.) was acquired on a 7T Bruker magnet using a spin-echo sequence (RARE) comprised of 50 slices with 6 averages. The SPECT (green, 600um voxels, 30min acq.) and CT (NIH Fire2, 400um voxels, 4.5min acq.) images were generated on a NanoSPECT/CT. 400 uCi of I125-beta-CIT (a dopamine and serotonin transporter imaging agent) was injected 4.5 hours prior to the SPECT study. Tracer localized in eyes, striatum and thyroid.
Animal was imaged on a Minerve bed under isoflurane. Data registration and presentation supported by inviCRO.

Options Details | Download | Contributor
3D ROI Tool
Contributor: inviCRO

Tags: Animation , Segmentation , Whole-body , Movie , Volume rendering

Visualization of a mouse atlas in inviCRO's new 3D ROI tool. This atlas is used by InVivoScope and VivoQuant to visualize bio distribution data and contains 24 regions.

Options Details | Download | Contributor
Rhesus Macaque Atlas Hemisphere
Contributor: inviCRO

Tags: Other Species , Animation , Segmentation , Brain Study , Volume rendering

Brain image analysis of non-human primates may be greatly aided through the use of anatomical atlases.  This animated GIF shows a surface rendering of one hemisphere of inviCRO's 15-region rhesus macaque brain atlas.

Options Details | Download | Contributor
« | < | 1 | > | »

User

Not logged in.
Username:
Password:

SPECT-CT.com

Links

Tag cloud


Partner cloud