spect/ct.com
       
 

 

 

 

 

  You are logged in as: AN18203 []
  Show NanoSPECT studies: All
 [144 hits] | Set 1| Set 2| Set 3| Set 4| Set 5| Set 6| Set 7| Set 8| Set 9| Set 10| Set 11| Set 12| Set 13| Set 14| Set 15
 
Multi-Mouse Bed: Three Mice SPECT/CT
OSSKI, Hungary | Mouse, SPECT/CT, Tc-99m
  Comments
  The images shows the simultanious acquisition of three mice using the Bioscan multi-mouse bed, which allows to image up to six mice in one run.

This study demonstrates a multi-phase MDP study, showing 3 different phases of the biodistribution of the radiotracer at the same time.
All mice were injected 40 MBq of Tc-99m labeled MDP, 90, 60 and 30 minutes respectively before the scan.

Using standard rat apertures, the acqusition took 18 minutes.
details edit download original
 
Mouse CT Volume Rendering (bone)
SPECT-CT.com | Mouse, CT only
  Comments
  Volume rendering of a mouse CT scan, measured on a NanoSPECT, rendered in IVS. Opacity level was set to display bones.
details edit download original
 
Respiratory cycle CT scan (mouse)
Bioscan, Inc. | Mouse, CT only, CT only, Dynamic/Gated
  Comments
  CT scan of a mouse illustrating respiratory cycle.

No additional hardware required.
details edit download original
 
Mouse Bone/Thyroid Dual-Isotope Scan (MIP, Tc-99m, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  Maximum Intensity Projection (MIP) of a dual-isotope (Tc-99m and I-123) SPECT/CT mouse study.

Injected activities:
Tc-99m-MDP: 1mCi
I-123-DOTA-G1: 200 uCi

Scan times:
CT : 7.5 min
SPECT: 40 min
(both isotopes imaged simultaneously)
details edit download original
 
Mouse Cardiac/Thyroid Dual-Isotope Scan (Slices, Tc-99m/MIBI, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  High resolution mouse cardiac study usuing Tc-99m labeled MIBI. Additionally, the mouse was injected straight I-123 showing up in the thyroids.

Injected activities:
Tc-99m/MIBI: 1 mCi
I-123 : 100 uCi

Scan times:
CT : 3 min
SPECT: 25 min
(both isotopes imaged simultaniously)

[Tracer Details]

details edit download original
 
Rat Lung Scan (Tc-99m MAA)
Erasmus MC, Rotterdam | Rat, SPECT/CT, Tc-99m
  Comments
  Scan of a rat lung using Tc-99m MAA (macro aggregate albumin), 30 minutes after injection of 1 mCi of the tracer.
The total scan length was 15 minutes.
details edit download original
 
Cardiac Mouse Study (Tc-99m MIBI)
Erasmus MC, Rotterdam | Mouse, SPECT/CT, Tc-99m
  Comments
  Cardiac study in mouse
1.3 mCi of Tc-99m labeled MIBI

9-pinhole aperture, 1.4 mm diameter

total scan time: 20 min.

[Tracer Details]

details edit download original
 
UHR Rat Bone Scan (Movie)
Erasmus MC, Rotterdam | Rat, SPECT only, Lu-177
  Comments
  Rat, 400g, 60x250mm

6mCi Lu177-Chloride
9-pinhole UHR rat aperture, Ø=1.5mm
1h scan, 6h p.i.
details edit download original
 
Dynamic Tumor Study (In-111 Dotatate, Mouse)
Erasmus MC, Rotterdam | Mouse, SPECT/CT, Dynamic/Gated, In-111
  Comments
  Dynamic tumor study in mouse.
1.9 mCi of Indium-111-Dotatate injected.
Measured 29 scans of 2 minutes each using the high sensitivity mouse aperture (APT1, 9-pinholes, 1.4 mm diameter) on a scan range of 35 mm. 16 projections per cycle, 2 cycles per study.
Total scan time was 1 hour.

Please note, the animal moved slightly at end of measurement.
details edit download original
 
Gerbil - Brain scan
Ghent University | Mouse, SPECT only, Tc-99m
  Comments
  Measurement performed on a Bioscan HiSPECT system.

Gerbil, female, 2 months
IV injection of 99mTc-ethylcysteinate dimer, 800µCi

Acquisition time: 20 minutes.


By courtesy of Kathelijne Peremans.
details edit download original