spect/ct.com
       
 

 

 

 

 

  You are logged in as: AN65331 []
  Show NanoSPECT studies: I-123
 
Quintuple Image Co-Registration
inviCRO, Boston | Rat, SPECT/CT, Tc-99m, I-123, In-111, Tl-201, Animation
  Comments
  A quadruple isotope SPECT/CT imaging acquisition was performed on a rat. 450uCi (17MBq) of Tc99m-MDP, 1.4mCi (52MBq) of I123, 600uCi (22MBq) of In111, and 1mCi (37MBq) of Tl201-Chloride were administered to the rat. A 40-minute image acquisition was performed at 3 hours post-injection of the Tc99m/I123 and 1 hour post-injection of the In111/Tl201.

The color bars from left to right are:
CT, Tc99m, I123, In111 and Tl201.

Please see [158] for more details.

Data courtesy of the University of New Mexico College of Pharmacy.
details edit download original
 
Quadruple-isotope imaging in a rat
University of New Mexico | Rat, SPECT only, Dual-Isotope, Tc-99m, I-123, In-111, Tl-201
  Comments
  A quadruple isotope SPECT/CT imaging acquisition was performed on a rat. 450uCi (17MBq) of Tc99m-MDP, 1.4mCi (52MBq) of I123, 600uCi (22MBq) of In111, and 1mCi (37MBq) of Tl201-Chloride were administered to the rat. A 40-minute image acquisition was performed at 3 hours post-injection of the Tc99m/I123 and 1 hour post-injection of the In111/Tl201. From left to right, the image displays reconstructions of Tc99m (gray; bone uptake), I123 (purple; thyroid and small intestine uptake), In111 (blue; heart, liver, and intestine uptake), and Tl201 (red; kidney, liver, and heart uptake).

Images courtesy of the University of New Mexico College of Pharmacy.
details edit download original
 
Triple-isotope imaging of a mouse
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123, Tl-201
  Comments
  SPECT/CT imaging of a mouse was performed following administration of three isotopes. 700uCi (26MBq) of Tc99m-MDP, 1.2mCi (44MBq) of I123, and 300uCi (11MBq) of Tl201 were injected. Imaging was performed for 56 minutes at 60 minutes post-injection. MDP bone uptake is visualized in gray, I123 uptake (red) is clearly visible in the thyroid, small intestine, and eyes, while Tl201 (green) uptake is mostly evident in the kidneys.

Images courtesy of The University of New Mexico College of Pharmacy.
details edit download original
 
Demonstration of crosstalk correction between Tc-99m and I-123
University of New Mexico | Rat, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  Dual-isotope SPECT/CT imaging was performed on a rat following administration of Tc99m-MDP (450uCi, 17MBq) and I123 (1.4mCi, 52MBq). Image data were acquired for 60 minutes at 60 minutes post-injection. The image displays two reconstructions of the Tc99m SPECT projection data. In the left-hand image, no corrections have been included to account for crosstalk of down-scattered I123 photons into the Tc<up>99m energy window. Therefore, uptake in the thyroid and small intestine is clearly visible. In the right-hand image, a crosstalk correction method has been applied. The evidence of the I123 distribution is eliminated without degradation of the reconstruction of the Tc99m distribution.

Images courtesy of The University of New Mexico, College of Pharmacy.
details edit download original
 
Mouse Bone/Thyroid Dual-Isotope Scan (Fusion, Tc-99m, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  As published by the Molecular Imaging Center for Excellence newsletter, SNM publication Volume 2, 2008-1:

Maximum Intensity Projection (MIP) of a dual-isotope (Tc-99m and I-123) SPECT/CT mouse study. All combinations of fusions of CT with Tc-99m- and I-123-SPECT are shown here.

Please note in particular, that the energy resolution of the NanoSPECT is good enough to resolve Tc-99m (140.5 keV) and I-123 (159.0 keV) while still providing the high sensitivity.

Injected activities:
Tc-99m/MDP: 1mCi
I123/LabeledCompound: 200 uCi

Scan times:
CT : 7.5 min
SPECT: 40 min
(both isotopes imaged simultaniously)

Original publication: 2007-02-26

Animated movie is available here [87].
details edit download original
 
Mouse Bone/Thyroid Dual-Isotope Scan (MIP, Tc-99m, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  Maximum Intensity Projection (MIP) of a dual-isotope (Tc-99m and I-123) SPECT/CT mouse study.

Injected activities:
Tc-99m-MDP: 1mCi
I-123-DOTA-G1: 200 uCi

Scan times:
CT : 7.5 min
SPECT: 40 min
(both isotopes imaged simultaneously)
details edit download original
 
Mouse Cardiac/Thyroid Dual-Isotope Scan (Slices, Tc-99m/MIBI, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  High resolution mouse cardiac study usuing Tc-99m labeled MIBI. Additionally, the mouse was injected straight I-123 showing up in the thyroids.

Injected activities:
Tc-99m/MIBI: 1 mCi
I-123 : 100 uCi

Scan times:
CT : 3 min
SPECT: 25 min
(both isotopes imaged simultaniously)

[Tracer Details]

details edit download original
 
Quintuple Image Co-Registration (Checkerboard)
inviCRO, Boston | Rat, SPECT/CT, Tc-99m, I-123, In-111, Tl-201, Animation
  Comments
  A quadruple isotope SPECT/CT imaging acquisition was performed on a rat. 450uCi (17MBq) of Tc99m-MDP, 1.4mCi (52MBq) of I123, 600uCi (22MBq) of In111, and 1mCi (37MBq) of Tl201-Chloride were administered to the rat. A 40-minute image acquisition was performed at 3 hours post-injection of the Tc99m/I123 and 1 hour post-injection of the In111/Tl201.

The color bars from left to right are:
CT, Tc99m, I123, In111 and Tl201.

Please see [158] for more details.

Data courtesy of the University of New Mexico College of Pharmacy.
details edit download original
 
Mouse Cardiac/Thyroid Dual-Isotope Scan (Fusion, Tc-99m/MIBI, I-123)
University of New Mexico | Mouse, SPECT/CT, Dual-Isotope, Tc-99m, I-123
  Comments
  High resolution mouse cardiac study usuing Tc-99m labeled MIBI. Additionally, the mouse was injected straight I-123 showing up in the thyroids. All combinations of fusions of CT with Tc-99m- and I-123- SPECT are shown here.

Marked with a cross is the mouse heart.

Please note in particular, that the energy resolution of the NanoSPECT is good enough to resolve Tc-99m (140.5 keV) and I-123 (159.0 keV) while still providing the high sensitivity.

Injected activities:
Tc-99m/MDP: 1 mCi
I-123 : 100 uCi

Scan times:
CT : 3 min
SPECT: 25 min
(both isotopes imaged simultaniously)

[Tracer Details]

details edit download original